Chapter 23 VLAN Stacking
MES3500-24/24F User’s Guide
180
adding tag 37 to distinguish customer A and tag 48 to distinguish customer B at edge device 1 and
then stripping those tags at edge device 2 as the data frames leave the network.
then stripping those tags at edge device 2 as the data frames leave the network.
Figure 89
VLAN Stacking Example
23.2 VLAN Stacking Port Roles
Each port can have three VLAN stacking “roles”, Normal, Access Port and Tunnel Port (the latter
is for Gigabit ports only).
is for Gigabit ports only).
• Select Normal for “regular” (non-VLAN stacking) IEEE 802.1Q frame switching.
• Select Access Port for ingress ports on the service provider's edge devices (1 and 2 in the VLAN
• Select Access Port for ingress ports on the service provider's edge devices (1 and 2 in the VLAN
stacking example figure). The incoming frame is treated as "untagged", so a second VLAN tag
(outer VLAN tag) can be added.
(outer VLAN tag) can be added.
Note: Static VLAN Tx Tagging MUST be disabled on a port where you choose Normal or
Access Port.
• Select Tunnel Port (available for Gigabit ports only) for egress ports at the edge of the service
provider's network. All VLANs belonging to a customer can be aggregated into a single service
provider's VLAN (using the outer VLAN tag defined by the Service Provider’s (SP) VLAN ID
(VID)).
provider's VLAN (using the outer VLAN tag defined by the Service Provider’s (SP) VLAN ID
(VID)).
Note: Static VLAN Tx Tagging MUST be enabled on a port where you choose Tunnel
Port.