ZyXEL Communications MES3500-24 Benutzerhandbuch

Seite von 349
Chapter 30 sFlow
MES3500-24/24F User’s Guide
246
30.2  sFlow Port Configuration
Click Advanced Application > sFlow in the navigation panel to display the screen as shown. 
Figure 136   
Advanced Application > sFlow 
The following table describes the labels in this screen. 
Table 91   
Advanced Application > sFlow 
LABEL
DESCRIPTION
Active
Select this to enable the sFlow agent on the Switch.
Apply
Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these 
changes if it is turned off or loses power, so use the Save link on the top navigation panel to 
save your changes to the non-volatile memory when you are done configuring.
Cancel
Click Cancel to begin configuring this screen afresh.
Port
This field displays the port number.
*
Use this row to make the setting the same for all ports. Use this row first and then make 
adjustments on a port-by-port basis. 
Note: Changes in this row are copied to all the ports as soon as you make them.
Active
Select this to allow the Switch to monitor traffic on this port and generate and send sFlow 
datagram to the specified collector. 
Sample-rate 
Enter a number (N) from 256 to 65535. The Switch captures every one out of N packets for 
this port and creates sFlow datagram.
poll-interval 
Specify a time interval (from 20 to 120 in seconds) the Switch waits before sending the 
sFlow datagram and packet counters for this port to the collector.