Commissioning (software) 
 
4.12 Deleting data 
 
D410 
114
 
Commissioning Manual, 08/2008 Edition 
Saving user data 
The "Copy RAM to ROM" function is used in SIMOTION SCOUT to save the following data 
from RAM to the CompactFlash card: 
●  The technology data / user data from the "volatile data" area 
●  Baud rate, PROFIBUS DP addresses, IP address, subnet mask and router address, 
including the retain variables with their initial values from the "non-volatile data" area 
 
 
 
Note 
The "Copy RAM to ROM" command cannot be used to save the actual value of retain 
variables to the CompactFlash Card. 
Execute the "Copy RAM to ROM" function separately for SINAMICS Integrated. This 
requires that the drive element has been selected in the Project Navigator. 
See also 
4.12 
Deleting data 
4.12.1 
Overview of data deletion 
You can define the scope of data to be deleted from SIMOTION D410 memory described in 
the "user memory concept". That is, you can choose to delete all data or only specific parts. 
You have the following options of deleting data from SIMOTION D410: 
●  Resetting the memory of SIMOTION D410 
●  Deleting user data from the CompactFlash Card 
●  Restoring the default settings of SINAMICS Integrated 