Siemens D410 Benutzerhandbuch

Seite von 150
 
Configuring SIMOTION D410 
 
3.4 Configuring PROFINET (only for D410 PN) 
D410 
Commissioning Manual, 08/2008 Edition 
53
 
3.4.2 
Operating SIMOTION D410 PN on PROFINET 
PROFINET interfaces (X200, X201) 
SIMOTION D410 PN provides a dual-port PROFINET interface (X200 and X201). The 
interface supports transmission rates as high as 100 Mbit/s. It can also be operated 
isochronous and equidistant. The autocrossing functionality means both crossed and 
uncrossed cables can be used 
A port has two integrated LEDs, a green LED and an orange LED. The following LED states 
can occur: 
Table 3-3 
LED states of the LED on the port of the PROFINET interface 
LEDs 
State 
Meaning 
Green 
LED off 
No connection to an active partner exists. 
 
LED on 
A connection to an active partner exists. 
Orange 
LED off 
No data is being exchanged. 
 
LED flashing 
Data is being exchanged over the port. 
The LED flashes irregularly depending on the data 
exchange,  
i.e. the LED does not flash with a specific frequency. 
 
Properties of PROFINET on SIMOTION D410 PN 
SIMOTION D410 PN on PROFINET supports the following properties 
●  PROFINET specifies operation at 100 Mbit/s. 
●  The minimum send cycle is 0.5 ms, and the maximum is 4 ms. 
●  The setting accuracy for the send cycle is 125 μs. 
The use of cycle reduction is possible for the D410. Detailed information concerning cycle 
reduction is available in the SIMOTION SCOUT Communication System Manual.