Installing the Dialogic® 
Brooktrout® TruFax® BRI 
PCI Board
Part Number: 931-107-05
The Dialogic® Brooktrout® TruFax® BRI 
(Basic Rate Interface ISDN) PCI boards are half-
sized, single-slot PCI-bus compatible fax processing 
boards. They provide the following:
Š
On-board BRI connections
Š
Up to four V.17 fax channels per board
The TruFax® BRI PCI Series boards can be used in 
either 3.3V or 5V bus (signaling) slots.
You need a fax application to use a TruFax® BRI 
board. Dialogic does not provide the application or a 
driver for this board. A driver comes with the 
application that you purchase.
This installation guide provides information about:
Š
System Requirements (including telephone 
service)
Š
Š
Š
Š
Š
Š
Š
Š
System Requirements
This board must be installed in an enclosure that 
meets the following specifications:
Š
A Pentium or later host processor
Š
A PCI bus slot that runs at least 33 MHz and is 
32 or 64 bits wide. See 
more information.
Š
Temperature: 0 C - 50 C
Š
Humidity: 10% - 95% (non-condensing)
Š
Power Requirements:
The following is also required:
Š
Telephone service: BRI interface
Setting the Module Number
Set each board to a unique module number to easily 
identify the resources associated with a specific board 
in a multi-board system.
Use the SW-1 rotary switch (Figure 1) to set a unique 
module number for each Dialogic® Brooktrout® 
board. See Figure 5 for the switch location. Select a 
number from 2 - F on the rotary switch. Settings 0 and 
1 are reserved and cannot be used. 
Figure 1. Rotary Switch (SW-1)
Setting Termination Jumpers 
for the BRI Line
Before installing your board, set termination for the 
BRI line if necessary. See Figure 5 for the location of 
the termination switches. 
Set jumpers as follows (See Figure 2 for details):
Figure 2. Termination Jumpers
Š
When the jumpers are removed from both 
switches for the appropriate port, there is no 
termination.
Š
When jumpers are present, the lines are 
terminated with 100
 ohms (this is how the boards 
are shipped).
Š
Dialogic does not support any configuration 
except the two illustrated in Figure 2.
Installing the Dialogic® 
Brooktrout® Board
To install your board:
1.
Turn off your PC and remove the cover.
2.
If the system has a PCI expansion hold-down bar, 
remove it.
3.
Locate a free PCI bus slot and remove the slot 
cover.
4.
Carefully align the board with the slot and firmly 
seat the board into the slot.
5.
Tighten the mounting bracket screw to secure the 
board to the chassis.
6.
Replace the cover.
7.
Turn on your computer.
Note: 
Dialogic® Brooktrout® boards should not be present in the 
computer during the installation of any operating system. 
The operating system might misinterpret the board as being 
some other device, with unpredictable consequences.
Recognizing PCI Slots
The PCI connectors in the computer chassis usually 
appear as white slots. The TruFax® BRI board has a 
PCI board edge connector. It can be inserted into any 
of the PCI slots shown in Figure 3
Figure 3. PCI Slots
Connecting the Phone Service
The appropriate telephone service and hookups must 
be installed at your site in order to connect to 
telephone service. The following table shows the 
channel/port relationship: 
 
Use the cable supplied with the board. Use these 
instructions to connect your board to BRI service:
1.
Plug one end of the cable into the telephone 
connector on the board.
Connect to Port A for channels 0 and 1 or to 
Port B for channels 2 and 3 (see Figure 5 to 
locate ports).
2.
Plug the other end into the wall connector for 
your BRI service.
Note: 
Port B is not present on the TruFax® BRI single port 
version.
Board
+5 V  +3.3 V +12 V -12 V Total Power
Single channel
0.8A 0A
0A
0A
4.0 W
Dual channel
0.9A 0A
0A
0A
4.5 W
Caution: A small amount of static electricity can destroy 
the sensitive components on your board. To prevent 
static damage, always connect yourself to ground using 
a ground strap before touching a circuit board. Handle 
boards only by the edges or metal mounting brackets 
and transport boards in an anti-static bag.
Warning: When installing the board, be sure that the 
mounting bracket is securely fastened to the chassis and 
the chassis is plugged into a grounded three prong plug. 
Improper chassis or bracket grounding can result in 
harmful or fatal electrical shock as well as component 
damage.
Jumper is in place
(ISDN BRI line is terminated)
Jumper is removed
(ISDN BRI line is not terminated)
Channel Number
RJ-45 Port
Type of Service
0
1
2
3
A
A
B
B
BRI S/T
BRI S/T
BRI S/T
BRI S/T
5V 64-Bit Connector
3.3V 32-Bit Connector
Insert the connector into any of these slots.
3.3V 64-Bit Connector
5V 32-Bit Connector
Universal PCI Board Edge Connector