Infocus C95 Benutzerhandbuch

Seite von 12
Projector Control
Page 5
Version 1.
Currently there is only one type of body so the size is fixed to 0x0006. The CRC field contains the CRC of the message.
The CRC algorithm is given in Appendix 1. To disable CRC set CRC_lo=0x00 and CRC_hi = 0x00.
The Message Head – if the CRC are disabled – then looks like the following string:
0xBE  0xEF 0x80 0x06 0x00 0x00 0x00.
 
This Head will be present in all strings sent to the projector from the host.
4.1.2  Message Body
The message body has the following structure:
Byte 0
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Operation Type
Function
Value
OpTypeLo
0x00
FuncNum_lo
0x00
Opval_lo
Opval_hi
Table 6
4.1.2.1  Field description
Field Name
Field Value
Description
OpTypeLo
0x01
Operation Set. Set current value
0x02
Operation Get. Gets the current value
0x03
Operation Initialize. Initialize the value to default.
Should not be used
0x04
Operation Increment. Increment the value by one
step. Only valid for “Adjust” functions.
0x05
Operation Decrement. Decrement the value by one
step. Only valid for “Adjust” functions.
Operation Type
0x06
Operation Execute. Execute the operation. Only
used for “Execute” operations
Function
FuncNum
The actual function number to execute. A list of
usable FuncNum is given in Chapter 9
Value
-
Only used by Operation Set. The actual value to set
the operation to. For all other operation actions, this
field is set to 0x0000.
Table 7