Summit HL-630 OPC Benutzerhandbuch

Seite von 46
 
25
 
 
 
 
 
 
Okidata C3000 Series 
Okidata OPC Color Cartridge Part #  42126661, 
42126660, 42126659, 42126658 
OEM Stated Yield: 15,000 All 
 
These machines have a glass fuse that is used to 
reset the machine.  The fuse is located in the gear 
end cap of the cartridge. We have not confirmed this 
yet, but we believe that the fuse is the same as the 
SF-5100.  The fuse must be replaced each cycle. 
 
 
 
 
 
 
Okidata C5100 Series 
Okidata OPC Color Cartridge Part #  42126604, 
42126603, 42126602, 42126601 
OEM Stated Yield: 15,000 All 
 
These machines have a glass fuse that is used to 
reset the machine.  The fuse is located in the gear 
end cap of the cartridge. We have not confirmed this 
yet, but we believe that the fuse is the same as the 
SF-5100.  The fuse must be replaced each cycle 
 
 
 
 
 
 
 
Okidata OL-400/800 OPC 
Okidata OPC cartridge part #
 
56106601 
OEM Stated Yield: 15,000 
 
Although all of these machines use the same 
cartridge, the reset procedures are different. 
 
 
Reset procedure for the Okidata OL-800 Series 
Printers 
 
Turn off the printer 
While holding the MENU1/MENU2 button down, 
turn the printer back on. Keep holding the button 
down until you see "MAINTENANCE MODE" on 
the display panel. Release the button. 
Press the MENU1/MENU2 button three times. The 
display will read "DRUM COUNT RESET". 
Press the ENTER/QUIET button. The display will 
read "DRUM COUNT RESET RESETTING", then 
"INITIALIZING", then "WARMING UP", and 
finally "ON LINE". The counter is reset! 
 
Reset procedure for all other OL series Laser 
Printers. 
 
Turn the printer off. 
Press and hold the RESET button (not the Menu 
Reset), and turn the printer on. Hold the button down 
until you see "DRUM RESET" on the display. 
Release the button.  
Run a self-test. Turn the printer off-line and press 
the PRINT  
FONT/SELF TEST button once and release. The 
printer will print out a page with the installed fonts, 
and the page count of the printer.  
 
Reset procedure for the "DOC-IT" Document 
Processing Systems
 
Turn the DOC-IT on, and re-initialize it: either re-
boot the computer, or type DOCIT at the DOS 
prompt and press enter. 
Press and hold the ENTER key for 3 seconds, when 
you release it you should see "Administration" on 
the display. 
Press the down arrow key until you see: Reset drum 
ctr.? YES/NO 
Press the left arrow key to move the check mark next 
to "YES". Then  
Press ENTER. 
Press any key to leave the Administration menu. 
The counter is reset!