Summit HL-630 OPC Benutzerhandbuch

Seite von 46
 
38
 
OEM Stated Yield: 20,000 (All) 
 
These cartridges do not use any reset procedures at 
all. According to the Sharp manual, they should be 
replaced when the copy quality deteriorates. No 
codes will show on the display to change the 
cartridge.  NOTE: None of these cartridges are 
interchangeable, they all are slightly different. 
 
Sharp AL-800 
Sharp Part # AL-80DR 
OEM Stated Yield: 20,000  
 
Open the front cover, and turn the power on. While 
pressing and holding both the “Exposure mode” and 
the “Clear key”, close the front cover.  Continue to 
hold these keys for 5 seconds, until the drum light 
goes out.  
 
 
 
 
 
 
Xerox XE60/80 
Xerox Cartridge Part # 13R553 
OEM Stated Yield: 18,000 
 
With the power on, open the front door. Hold the 
“Copy Contrast” button while closing the front door, 
continue holding the button down for 3 seconds, 
then release. 
 
Sharp JX-9500 OPC/Toner 
Sharp Cartridge Part # JX-95DR 
OEM Stated Yield: 50,000 OPC, 25,000 Toner 
 
There is a glass fuse located under a clip on the top 
of the cartridge. Replace the fuse each cycle. The 
fuse is a 250V, 80mA, 5x20mm fast acting glass 
type. The toner waste bottle also uses a fuse- a 
250V, 50Ma 5x20mm fast acting glass type. 
 
 
 
 
 
 
 
 
Sharp JX-9600 Toner Cartridge 
Sharp Cartridge Part # JX-96ND 
OEM Stated Yield: 15,000 
 
This cartridge needs to have the fuse replaced each 
cycle. The replacement fuses are physically different 
from the OEM but work the same. The fuses for this 
cartridge are a special, very fast acting, type and 
must be ordered from your supplier.  The 
replacement fuse must be inserted across the two 
screws as shown. We have found it best to use solid 
telephone wire and wire wrap around the fuse posts. 
Soldering wires to the fuse can cause the 
 fuse to blow if too much heat is used.  
 
 
 
 
 
Sharp JX-9600 OPC Cartridge 
 
With the exception of starter cartridges, these 
cartridges have a small board located on the end of 
the cartridge. The small surface mount micro fuse 
(125mA) must be replaced each cycle. If you have a 
starter cartridge the machine must be reset through 
the menu. (Starter cartridges do not have a fuse 
board.) Almost all of the machines have a different, 
and complicated reset procedure. Two of the most 
popular machines are listed below. Other machines 
probably also have a similar type of reset procedure, 
but we have not been able to confirm them. 
 
Sharp JX-9600 
Sharp OPC Cartridge Part # JX96DR 
OEM Stated Yield: 30,000 
Turn the printer off. 
With the MENU and ENTER keys depressed, turn 
the power on.