1.1 Introduction
 
(   ) 
iii
 
Important Information to the User 
 
 
In order to meet Product Safety, FCC and CE marking requirements, it is advised to use the power 
supply, power cord, and interface cable which were shipped with this product. Otherwise these 
devices need to meet following standards: 
 
Power Supply 
 
The power supply should follow UL/EN/IEC60950 certification, Class 1 power supply with 
SELV (Secondary Extra Low Voltage), non-energy hazard output, limited power source, 
input rated 100-240 Vac, 1.5/0.8 A, 50/60 Hz, output rated 24 Vdc, 3.15A.If this product is 
used with a power supply different from the Toshiba TEC power supply, you will need to 
test this power supply and the Toshiba TEC printer to comply to FCC and CE mark 
certification.  
 
Interface Cable 
 
You are advised to use a shielded (360 degree) interface cable with this product. The 
shield must be connected to the frame or earth ground connection or earth ground 
reference at BOTH ends of the cable. 
If another cable is used than described above you will need to test this cable with the 
Toshiba TEC printer and your system for FCC and CE mark certification.  
 
Power Cord 
 
For this product a UL listed, detachable power cord is required. When the power supply is 
mounted on the floor, a power cord with Type SJT marking is required. Outside the US, 
power cords need to meet the particular country’s certification and application 
requirements. If a power cord is used different from described above you might violate 
safety certifications which are in force in the country of use.   
The socket-outlet needs to be installed near the equipment and must be easily accessible.