Tally Genicom 6600 Benutzerhandbuch

Seite von 330
124
Chapter
7
Control Sequences
Valid Control Sequences
The following eleven control sequences are valid in Barcode/Block Character 
Mode:
^A
Move the Home.
^B
Select Horizontal Barcode.
^C
Select Vertical Barcode.
^D
Select Double Density Block Characters.
^M
Select Normal Density Block Characters.
^N
Select New Introducer.
^R
Relative Cursor Move.
^S
Signed Cursor Move.
^T
Absolute Cursor Move.
^U
Set Unit Line.
^W
Set Barcode Density.
^A - Move The Home
Moves the Home pointer and homes the cursor.
Command ^A(home)NL
Arguments
(home)
The distance to move the Home pointer down in 
increments of 0.01 inches. Default is the current 
vertical position.
^B - Select Horizontal Barcode
Selects horizontal barcode and sets barcode parameters.
Command ^B(type);(height);(size);(option)NL
Arguments
^B
Selects Horizontal Barcode Command.
(type)
The style of Barcode (default = 1).
1 = Code 39
 
2 = Code 39 with Check Digit added.
 
3-5 = Not used.
 
6 = Two of five with 2:1 Ratio.
 
7 = Interleaved Two of Five with 2:1 Ratio.
 
8-9 = Not used.
 
10 = Two of Five with 3:1 Ratio.
 
11 = Interleaved Two of Five with 3:1 Ratio.
 
12 = UPC Version A, 10 Data Digits
 
13 = EAN-13
 
14 = EAN-8
(height)
Height of the individual bars in increments of 0.01 
inches, ranging from 1 - 255 (default = 80).