Tally Genicom 6600 Benutzerhandbuch

Seite von 330
Reverse Print Command (Create)
171
Reverse Print Command (Create)
This command allows you to define an area on a form where reverse printing 
(white ouput on black background) will be output.
Reverse printing cannot be used with OCR Characters or Overlay Data.
Table 15. Reverse Command
Field
Function
Option/Modifier Selections
REVERSE
This is the command specifier. 
Using the following parameters a 
field of reverse printing will be 
defined for a location on a form.
Enter REVERSE
D; 
 
Dark Printing
Optional parameter for changing 
horizontal dot density from 60 DPI 
to 120 DPI.
Enter D; or DARK; to select this option.
The SR, SC, ER, and EC parameters use the same methods for defining the REVERSE Print 
area. Whether in columns or dots depends on the SCALE Command. You may also use the 
XX.YY format for plotting duplication print locations explained earlier in the Standards Section.
SR;
Plots the starting ROW of the field.
Enter a value ranging from 1 to one less 
than the maximum form length and the 
delimiter.
SC;
Plots the starting COLUMN of the 
field.
Enter a value ranging from 1 to one less 
than the maximum form width and the 
delimiter.
ER;
Plots the ending ROW of the field. 
The ending row must be greater 
than the starting row.
Enter a range ranging from 2 to one less 
than the maximum form length and the 
delimiter.
EC
Plots the ending COLUMN of the 
field. The ending column must be 
greater than the starting column.
Enter a value ranging from 2 to the 
maximum form width.
STOP
Command Terminator.
Enter STOP and the printer waits for a new 
command. Leave it out and the printer will 
wait for another REVERSE Command.