Tally Genicom 6600 Benutzerhandbuch

Seite von 330
Expanded Print Command (Normal and Execute)
193
Expanded Print Command (Normal and Execute)
This command allows you to expand alphanumeric characters horizontally 
and vertically.
Table 28. Expanded Print Command
Field
Function
Option/Modifier Selections
EXPAND;
Command Specifier. Instructs 
printer to enter Expanded Print 
mode.
Enter the current Special Function Control 
Character, followed by EXPAND, then end 
the entry with the parameter delimiter.
VE;
Vertical expansion amount.
Enter a value specifying the desired 
expansion factor, then end the entry with 
the parameter delimiter. Valid selections 
range from 0-113. A selection of 0 returns 
you to standard size characters.
HE
Horizontal expansion amount.
Enter a value specifying the desired 
expansion factor, then end the entry with 
the parameter delimiter. Valid selections 
range from 0-113. A selection of 0 returns 
you to standard size characters.