EMSA HS500E Benutzerhandbuch

Seite von 82
C H A P T E R   3 :   R F I D   C O M M A N D S  
3 . 1 . 2   R e s p o n s e  
P a c k e t   S t r u c t u r e   Ta b l e  
W o r d  
#  
M S B  
L S B  
D e s c r i p t i o n  
01 
00 
06 (+ 
number of 
returned 
data words, 
if any)   
OVERALL LENGTH: 
The first word in a response packet is the Overall 
Length
. This 2-byte value indicates the total 
number of words in the response (including this - 
the Overall Length field). Length will always be at 
least six words (0x0006).  
(RF 
Error)  
(Command 
Echo / Error 
Code) 
RF ERROR 
COUNTER:
  
The MSB of the second 
word holds the single-
byte RF Error Counter. 
This value identifies the 
number of times RF 
transmission failed or 
could not be completed 
for this command.
COMMAND ECHO / 
ERROR CODE: 
The Command Echo is 
returned in the LSB and 
displays the Hex value 
of the executed 
command.  
When an error occurs, 
the LSB will hold a 
single byte Error Code.
03 
(IC) 
(Node ID 
Echo) 0x01 
INSTANCE COUNTER: 
The MSB of word 03 
contains the Instance 
Counter. 
This single-
byte value is 
incremented by one 
following each response 
(range = 0x00 to 0x7F). 
Cycling power to the 
unit resets this counter 
to 0x00. 
NODE ID ECHO:  
The LSB of the third 
word, Node ID Echo
retrieves the Node ID of 
the antenna that 
executed the command 
(this value will always be 
0x01 for the HS500E).
04 
(RFT1) (RFT2) 
RF TIME: 
Word 04 of a response packet contains the RF 
Time. 
This two-byte value indicates the portion of 
the Timeout Value (set in the Command Packet) 
that remains after the completion of the command 
(see Total Time below). 
RF TIME = (TIMEOUT VALUE - TOTAL TIME) 
H S 5 0 0 E   –   O P E R A T O R ’ S   M A N U A L                                          
P / N :   1 7 - 1 3 0 5   R E V 0 2   ( 1 2 - 0 5 )  
P A G E   2 3   O F   8 2