After you have configured Node 01 via OnDemand Node Configuration, open your 
PLC control software (RSLogix 5000 for ControlLogix) and define two Controller 
Tags
 (a Write Tag and a Read Tag).  
Be sure to use the same Write Tag Name and Read Tag Name specified in the 
OnDemand Node Configuration
 (i.e., EMS_WRITE1 and EMS_READ1). 
These tags must also have the capacity to store an integer array equal to your 
previously specified Max Write/Read Size + 3 words.  
So for example, if the Max Read Size you specified earlier was 100 words, the 
corresponding Read Tag in the PLC must be able to store an array of 103 integers.  
 
 
5 . 3 . 1  
C o n t r o l l e r   Ta g s   S u m m a r y  
•  Write Tag holds PLC-bound response data written by the HS500E after 
executing a command.  
•  Read Tag holds HS500E-bound RFID commands and other instructions 
written by the Host. 
After creating and defining Write and Read Tags for the HS500E, return to the PC 
and the HS500E’s HTML Server – Main Page to continue. 
 