EMSA HS500E Benutzerhandbuch

Seite von 82
C H A P T E R   7 :   R A W   T C P / I P   P R O T O C O L  
7 . 2 . 2  
R A W   T C P / I P   R e s p o n s e   E x a m p l e  
The following is the response to the Read Data command issued in the previous 
example:  
 Word  MSB 
LSB 
Description 
01 
FF 
01 
“Raw TCP/IP” 2-byte Response Header: 
MSB = 0xFF 
LSB = Node ID Echo (0x01 for the HS500E) 
02 
00 09 
Overall Length of response packet (not 
including the 2-byte header) 
03 
AA 
02 
MSB = AA 
LSB =  Command Echo: Read Data 
04 
ICV 01 
MSB 
Instance Counter Value 
LSB = Node ID Echo 
05 
05 1b 
Time Stamp (Month – Day) 
06 
01 0C 
Time Stamp (Hour – Minute) 
07 
21 06 
MSB 
Time Stamp (Seconds) 
LSB = Number of Additional Data Bytes  
Returned 
08 
61 62 
Returned Data Bytes 1 & 2 
09 
63 64 
Returned Data Bytes 3 & 4 
0A 
65 66 
Returned Data Bytes 5 & 6 
H S 5 0 0 E   –   O P E R A T O R ’ S   M A N U A L                                          
P / N :   1 7 - 1 3 0 5   R E V 0 2   ( 1 2 - 0 5 )  
P A G E   5 9   O F   8 2