Citizen Systems CT-S310 Betriebsanweisung
— 25 —
5. OTHER
5.1 External Views and Dimensions
(Unit: millimeter)
Built-in Power Supply Type
AC Adapter Type
195
121
84
145
159
86
145
195
5.2 Manual Setting of Memory Switch
Memory switches can be set manually or by a command.
For manual setting, refer to the next page.
The function of each memory switch is shown in the following table.
(The
For manual setting, refer to the next page.
The function of each memory switch is shown in the following table.
(The
white-on-black characters
are factory setting.)
Switch No.
Setting
0 (OFF)
1 (ON)
Memory SW1-1
Power ON Info
Valid
Not send
SW1-2
Buffer Size
4K bytes
45 bytes
SW1-3
Busy Condition
Full/Err
Full
SW1-4
Receive Error
Print ?
No Print
SW1-5
CR mode
Ignored
LF
SW1-6
Reserved
Fixed
−
SW1-7
DSR Signal
Invalid
Valid
SW1-8
Init Signal
Invalid
Valid
Memory SW2-1
Reserved
−
Fixed
SW2-2
Auto Cutter
Invalid
Valid
SW2-3
Spool Print
Invalid
Valid
SW2-4
Full Col Print
LineFeed
WaitData
SW2-5
Resume aft PE
Next
Top
SW2-6
Paper width
80mm
58mm
SW2-7
Reserved
Fixed
−
SW2-8
PNE Sensor
Valid
Invalid