8-3. Description of Input / Output Signals
8-3-1. Input / Output Signals
a)
 
Input / Output Signals
*DATA       
: 8 bit parallel signal. (Positive logic)
*STB         
: A strobe signal for reading in 8 bit data. (Negative logic)
*RESET   
: A signal which resets the entire printer. (Negative logic, 1 ms or more)
b)
 
Output Signals (From Printer)
*ACK         
: This is a pulse signal for requesting 8 bit data, issued at the end of a BUSY
 
 signal. (Negative logic)
*BUSY     
: This signal indicates that your printer is in a BUSY state.
  New data should be input when this signal is “LOU”. (Positive logic)
*FAULT   
: When your printer is in an alarm state, this signal is “LOW”. At this time,
  all control circuits of your printer are interrupted. (Negative logic)
Note: An alarm condition occurs when the timing of the print head movement sensor is abnormal.
c)
 
Power Source
*”H” Level         
: H level out put for TTL level
*GND           : The common circuit ground.
*FRAME GND   
: Connect the shield of interface cable to this.