Citizen Systems 3541 Benutzerhandbuch

Seite von 48
iDP-3540/41 User’s Manual
 CITIZEN
32/48
2)
 
RS-422A type only
No.
Function
OFF
ON
Factory
Setting
1
2
L
H
OFF
2
2
Printer address
L
H
OFF
3
2
L
H
OFF
4
 
-
OFF
5
OFF
6
Baud rate setting
Refer to the table below
ON
7
ON
8
OFF
bps 110
150
300
600
1200 2400 4800 9600
No.
5
OFF
ON
OFF
ON
OFF
ON
OFF
ON
6
OFF
OFF
ON
ON
OFF
OFF
ON
ON
7
OFF
OFF
OFF
OFF
ON
ON
ON
ON
8
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
11-3. Slide Switch Setting (Serial interface specifications only)
RS-232C or 20mA current loop can selected by changing slide switch SW1 on the control board.
The side labeled “RS” is for RS-232C and the side labeled “CL” is for 20mA current loop.
The switch is set at the factor for RS-232C.
11-4. Dip-Switch Location
Power off and remove the printer cover before setting the Dip-Switches.
Notes: DS2 is mounted for Serial type and RS-422A type only.