Citizen Systems Model CMP-10 Benutzerhandbuch

Seite von 80
— 78 —
10.  AC ADAPTOR
(1)
Input voltage
100V ~ 240V AC (50/60 Hz)
(2)
Input current
250 mA
(3)
Rated output
9V ±5%
(4)
Efficiency
65% or more (AC 100V/50 Hz full load)
70% or more (AC 240V/50 Hz full load)
(5)
Ripple and noise voltage
Less than 150 mVp-p (9 VDC)
(6)
Insulation test
More than 100M ohm
(DC 500V, 1 minute, between primary and secondary circuit and chassis)
(7)
Leakage current
0.25 mA or less (AC 240V/50 Hz)
(8)
Temperature rise
45K or less on case surface (100 VAC/50 Hz full load @25°C)
(9)
Over voltage protection
120% - 150%
(10) Overload protection current
1.8 - 3.5A (AC 100-240, 25°C)
(11) No load power consumption
3W or less (AC 240V, 25°C)
(12) Safety standard
UL, C-UL, PSE (10AD-JU)
VDE, GS, CE (10AD-E)
(13) Size
10AD-JU - 75 mm (L) × 50 mm (W) × 30 mm (H)
(14) Case material
94V-1
(15) Cable
1828.8 mm  UL2468#22 × 2C
(16) Plug
3.5 × 1.3 × 9.5S
(17) Polarity
Center ”+”
(18) Weight
104 g ±5g
11.  EMI STANDARD
VCCI Class B
FCC Class B
EN55022