Citizen Systems CBM-231 Benutzerhandbuch

Seite von 64
CBM-230/231 User’s Manual
17
CITIZEN
6.3
Input / Output Signals
6.3.1 Input / Output Signals
(1) Input signals to the printer
• 
DATA
: This is an 8-bit parallel signal (Positive logic)
• 
STB
: This is a strobe signal to read in 8 -bit data (Negative logic)
• 
RESET
: This signal resets the entire printer (Negative logic) 1 ms or more
(2) Output signals from the printer
• 
ACK
: This is an 8-bit data request signal. Pulse signal output at the end of the BUSY signal
(Negative logic)
• 
BUSY
: This signal indicates the BUSY state of the printer. Enter new data when it is at LOW.
(Positive logic)
• 
FAULT
: This signal is set to low when the printer has an alarm. When this is done, all control
circuits in the printer stop.(Negative logic)
• 
PE
: This signal is output when the printing paper has run out or is running out.
(Positive logic)
• 
Drawer switch output
: This signal is set to HIGH when the switch is opened, and to LOW when shorted.
(3) Power signals
• 
+5VDC
: This is a 5 V output pulled up at a 3.3 k
Ω
resistor.
• 
GND
: This is a common ground on the circuits.