Citizen Systems CBM-231 Benutzerhandbuch

Seite von 64
CBM-230/231 User’s Manual
28
CITIZEN
9.2
Input Data Format
(1) Horizontal Tab Command (HT)
Code : [09]h
Mones the printing position to the next horizontal tab position
The horizontal tab position is set by ESC D. The initial setting of the horizontal tab position is every 8
characters (9th columns, 17th columns, 25th columns, 33rd columns, 41st columns) of Font A.
(2) Print command (CR)
Code : [0D]h
1) When the DIP switch segment DS1-8 is set to OFF
This command is ignored.
2) When the DIP switch segment DS 1- 8 is set to ON
Printing is done when the internal input buffer has the data. When it has no data, however, line feed is
done.
(3) Printing paper feed command (LF)
Code : [0A]h
Prints the data in the internal input buffer and feeds the line(s) based on the set line feed rate.
(4) Setting the right space amount of the characters (ESC SP n)
Code : [1B]h + [20]h + n
* {0
n
20}
The data is described with the hexadecimal code.
Set the right space of the amount of the character in term of dots (in an increment of 1/203 inch). As an
initial value, n=0. In the double width magnification mode, the right space amount is double the set amount.