Citizen Systems 291 Benutzerhandbuch

Seite von 60
CBM-290/291 User’s Manual
19
CITIZEN
7. Serial Interface
7.1 Specifications
(1) Data transfer system:
Asynchronous
(2) Baud rates
1200, 2400, 4800, 9600, 19200 bps (Selectable by user)
(3) Configuration of one word
Start bit :
1 bit
Data bit :
8 bits
Parity bit :
Add/even or no parity
(Selectable by user)
Stop bit :
1 bit or more
(4) Signal polarity
RS-232C
• 
Mark
=
logic " 1" (–3V
–12V)
• 
Space =
logic " 0" (+3V
+12V)
(5) Receiving data (RD signal)
RS-232C
• 
Mark
=
1
• 
Space =
0
(7) Receiving control (DTR signal)
RS-232C
• 
Mark
:
Data transfer not available
• 
Space :
Data transfer available
(8) Transmission control (TD signal)
DC1 code (11H) X-ON
:
Data reception available
DC3 code (13H) X-OFF
:
Data reception not available