Citizen Systems 291 Benutzerhandbuch

Seite von 60
CBM-290/291 User’s Manual
25
CITIZEN
9.2 Command Details
(1) Horizontal Tab Command (HT)
Code : (09)h
Shifts the printing position to the next horizontal tab position. The horizontal tab position is set by ESC D.
Initial setting of the horizontal tab position is each 8 characters in 9th, 17th, 25th, 33rd
,
columns.
(2) Print Command (CR)
Code : (0D)h
1) When DS 1 -2 is OFF:
This command is ignored.
2) When DS 1- 2 is ON:
With data held inside the internal print buffer, printing and line feed are performed.
Without data inside the internal print buffer, however, no printing is performed.
(3) Printing and Paper Feed Command (LF)
Code : (0A)h
Prints data inside the input buffer and feeds lines based on the line feed amount having been set.
(4) Setting the right space amount of the characters (ESC SP n)
Code : (1B)h + (20)h + n
* {0
n
20}
Data is described in Hex code.
The rightward space amount is set in dot unit (1/203 inch unit).
In the initial value, it is n=0.
The rightward space amount in double wide mode is made double of the set volume.
(5) Collective Specifying Printing Mode (ESC ! n)
Code:
(1B)h + (21)h + n
* {0
n
FF}
Data is described in Hex code.
Printing mode is assigned.
Each n bit indicates the following:
VALUE
BIT
FUNCTION
0
1
0
Character Font
Font A
Font B
1
Undefined
2
Undefined
3
High-lighting
Canceled
Specified
4
Double height
Canceled
Specified
5
Double width
Canceled
Specified
6
Undefined
7
Underline
Canceled