Citizen Systems iDP-3540/3541 Benutzerhandbuch

Seite von 48
iDP-3540/41 User’s Manual
 CITIZEN
41/48
12-2-21. Drive Pulse Duration Setting Command For the First Drawer
         1
st
 byte
                 D8
D1
  0
  0
  0
  1
  1
  0
  1
  1
ESC (1B) H
         2
nd
 byte
                 D8
D1
  0
  0
  0
  0
  0
  1
  1
  1
        BEL(07)H
         3
rd
 byte
                  D8
D1
n1
                                                                (DEFAULT=20)
         4
th
 byte
                  D8
D1
n2
                                                                (DEFAULT=20)
This command adjusts the drive pulse duration for the first drawer.
Pulse duration 
= 10 x n1 (ms)
Delay         
= 10 x n2 (ms)
 n1 
 127  default n1 = 20
 n2 
 127  default n2 = 20