Citizen Systems CD-S500 Benutzerhandbuch

Seite von 52
35
Soft SW Setting Mode
Setting the mode
1
. If the FEED switch is pressed once in
maintenance mode (POWER LED is
flashing), the POWER LED and PAPER
OUT LED start flashing.
2
. If the front cover is reopened and
closed in this status, the POWER LED
and PAPER OUT LED stop flashing to
and remain lit, and after the title and
top items have printed, it enters Soft
SW Setting Mode.
Flashing
Press once
Reopening and closing the front cover:
 Flashing       Lit
   Maint
enance Mode
HEX Dump Mode
Reopening and closing the front cover:
 Flashing       Lit
Setting the mode
If the front cover is reopened and closed
in maintenance mode (POWER LED is
flashing), the POWER LED stops flashing
and remains lit, and the printer enters
HEX Dump Mode.
After printing the title, it stands by to
receive data.
To leave HEX Dump Mode, turn off the
printer power then turn the power on again
with the front and rear covers both closed.