Setting Mode Table
 Soft Control-SW
   Maint
enance Mode
Set item
Initial value
Setting value
Remarks
Command Type
EPSON
EPSON
STAR
CBM1
CBM2
Number of Col.
40/33
40/33
42/35
Font Select
7x9
7Ω9
9Ω9
Paper Plies
OFF
OFF
2P
3P
Paper End
ENB
ENB
DIS
Paper Near-End
ENB
ENB
DIS
Slashed Zero
OFF
OFF
ON
Print Direct.
BI-DIR
BI-DIR
UNI-DIR
Auto LF
OFF
OFF
ON
Code Page
437
850, 860
863, 865
852, 866
857, 858
WPC1252
The  emulation  is  selected  from  EPSON/STAR/ 
CBM1/CBM2.
The  initial  font  size  is  selected  immediately  after  the 
power is turned on.
It sets whether or not slash is used with the numeral 0 
(zero).
Copy mode is selected.
OFF/2P/3P  can  be  selected.  But  when  3P  is  set,  the 
printing speed is low.
Designates  printing  direction.  When  BI-DIR  is  selected, 
printing starts from the closer of the left and right ends 
of  the  next  printing  line  from  the  print  stop  location. 
During UNI-DIR printing is usually done from the left end.
The PE signal enabled/disabled is set at paper end when 
only  the  centro-interface  is  set  as  enabled.  During 
enabled status, BUSY, PE, FAULT are output and printing 
stops at paper out. During disabled status, only BUSY is 
output and printing stops at paper out.
The code page is selected.
Number  of  full  dot  in  full  column  is  200  dots.  For  the 
number  of  line  columns  based  on  the  paper  width,  see 
“Setting the Paper Width and Printing Line Column Number”. 
The  LF  operation  during  CR  code  reception  is  selected. 
When ON, LF does not operate; when OFF, LF operates. 
CR: Carriage Return LF: Line Feed
The  PE  signal  enabled/disabled  is  set  at  paper  near  end 
when  only  the  centro-interface  is  set  as  enabled.  During 
enabled  status,  PE,  FAULT  are  output  and  printing 
continues. During disabled status, nothing is output and 
printing continues.
437,
KATAKANA,