Xerox 721P85530 Benutzerhandbuch

Seite von 488
PRINT FORMAT COMMANDS
XEROX DOCUPRINT 180 LPS PDL REFERENCE
6-21
LINE=(11,20),POS=1,FONT=3,POS=40,FONT=1,POS=80
     ,FONT=2,
LINE=(31,50),POS=1,FONT=2,POS=40,FONT=3,POS=80
     ,FONT=1;
Form and variable data
Under certain circumstances, a form and its associated variable 
data do not align properly, even though it appears that both use 
the same line spacing. Variable data has a line-spacing value 
that is computed as dots per line, and rounding is done on that 
value. In FDL, the rounding takes place only when it is needed 
to resolve to a dot address and, therefore, might involve more 
than one line at a time. Refer to the “Rounding measurements” 
section in the 
DocuPrint 180 LPS Forms Creation Guide
 for 
further information.
CME string constant
Whether a font switch is applied to a CME string constant 
depends upon the order in which FONT and CONSTANT are 
specified in the CME. If FONT is specified before CONSTANT, 
the font switch applies to the string constant. If FONT is 
specified after CONSTANT, the font switch occurs at the line 
position immediately after the string constant.
Where a CME string constant is printed on a line depends upon 
where the POSITION and CONSTANT parameters are 
specified in the CME. If POSITION is specified before 
CONSTANT, the string constant is printed at the specified 
position. If POSITION is specified after CONSTANT, the string 
constant is printed at the current position (position 1 if no other 
POSITION or CONSTANT parameter has been specified), and 
a subsequent CONSTANT or FONT parameter will take effect 
at the specified POSITION.
RSX11host type
When the host type is RSX11, CMEs are often applied twice 
per line because of the way the carriage return/line feed is 
processed. When mixing font switches and string constants, the 
string constants may appear twice and be overprinted with two 
different fonts. The recommended approach for RSX11 host 
types is to specify the string constant font before the string 
constant itself, such as:
FONT=1,CONSTANT=’string’,FONT=2;