Xerox 5252 Benutzerhandbuch

Seite von 348
DocuColor 5252 Operator Manual
6-19
Accessories
6
 A
cce
ss
o
ries
Control Panel
Figure 6-13
1
2
3
4
5
6
7
8
9
Name
Function
1
Ready light
The Ready light blinks during initialization and is constant when the EHCS is in use 
or in standby mode.
2
Sample set 
button
Press to have the EHCS deliver the next collated set to the top tray.
3
Unload 
button
Press once to lower the Stacker Tray and unlock the front door. If pressed while 
running a job, all sheets in the paper path are delivered before the Stacker Tray 
starts to lower. 
4
Unload light
Illuminates when the Stacker Tray has reached the down position and the front door 
can be opened.
5
Wait light
Blinks when the Stacker Tray is moving up or down.
6
Fault code 
display
Refer to the fault code table later in this section.
7
Top tray jam 
area
Blinks when there is a jam.
8
Bypass jam 
area
Blinks when there is a jam.
9
Stacker tray 
jam area
Blinks when there is a jam or the door is open.
Keypad
Used by the service representative for diagnostics (not shown). The keypad is 
located on the front right of the control panel.