4.  MAINTENANCE AND TROUBLESHOOTING
4.1  Setting/Replacing the paper roll
CAUTION!
■ Always use the specified types of paper roll.
■ Confirm that the paper roll is set correctly.
■ When the paper is skewed and not extended straightforward from under the printer
cover, open the printer cover and adjust the paper correctly.
■ When the cover is opened after paper setting, be sure to pull the paper straightforward
by several cm out of the printer, and then close the cover.
■ When closing the printer cover, press on the center part of the cover to close it firmly.
■ When setting paper, be careful not to have your finger injured by the paper edge.
WARNING
When opening the printer cover, DO NOT touch the print head or cutter blade.  Otherwise,
burning or injury of hand may result.
CAUTION!
■ If the cutter blade remains protruded with paper jammed, press the FEED button.  If the
cutter blade does not move back, performe the above step 1 through 3 and then turn
the printer on without a paper roll.  Contact your Citizen Systems dealer.  Be carefull
not to have your hand injured by the cutter blade in the operation.
■ The print head is hot immediately after printing.  DO NOT touch it with your hand.  DO
NOT touch the heating element of the head with a bare hand or metal object either.
See 5.3 Manual Setting of Memory Switch
1.
Lift the cover open button.
2.
Open the printer cover.
3.
Insert a paper roll with its print area facing down
as shown in the figure and pull out the paper
end straightforward by several cm out of the
printer.
4.
Firmly close the printer cover until a click can
be heard. With the factory setting, the paper is
fed and cut automatically.
4.2  Removing Jammed Paper
1.
Turn the printer power off.
2.
Open the printer cover.
3.
Remove the jammed paper including any paper chips remaining. (Remove
the paper roll set in the holder as well.)
4.
Reinstall the paper roll and close the printer cover.
5.
Turn on the printer.  The auto cutter mechanism is initialized and the alarm is
cleared.