5.4  Monitoring the Print Head Overheating
If the temperature exceeds 65°C for some reason, the printer
automatically stops printing with Power LED indication of “Error” to
protect the print head.
If the head temperature returns to 60°C or below, the printer is ready
for printing.
5.5  Self Testing and Internal Settings
● Keep the LF switch pressed down.
● Press the ON/OFF switch down.
● Release the ON/OFF switch.
● Release the LF switch.
Immediately after releasing the LF switch the printer will print out a
SELF TEST report.
At the end of the report, density, auto-power off time, head temperature,
battery output voltage, communication mode, baud rate (for serial
communication) are printed.
The number of marks * in the parentheses aside battery output voltage
shows a level of battery charge in 5 steps.
5.6  Print Area
4 mm
6 mm
Paper width - 58 mm
Print area - 48 mm
Print area
Thermal paper