Epson M X - 8 0 Benutzerhandbuch

Seite von 103
APPENDIX 2 Parallel Interface
Both the MX-80 Type II and MX-80 F/T Type II include a parallel interface as the
standard equipment, and this paragraph describes the parallel interface.
(1) Specifications
(a) Data transfer rate:
1000 CPS (min.)
(b) Synchronization:
By externally supplied STROBE pulses.
(c) Handshaking:
By ACKN LG or BUSY signals.
(d) Logic level:
I n p u t   d a t a   a n d   a l l   i n t e r f a c e   c o n t r o l   s i g n a l s   a r e
compatible with the TTL level.
(2) Connector
Plug: 57-30360 (AMPHENOL)
It is recommended that interface cables be kept as short as possible.
(3) Connector pin assignment and descriptions of signals.
Connector pin assignment and descriptions of respective interface signals are
provided in Table A2-1.
Table A2-1 Connector Pin Assignment and Descriptions of Interface Signals
Description
STROBE pulse to read data in. Pulse
width must be more than 0.5µs at receiv-
ing terminal.
The signal level is normally “HIGH”; read-
in of data is performed at the “LOW”
level of this signal.
These signals represent information of the
1st to 8th bits of parallel data respectively.
Each signal is at “HIGH” level when data
is logical “I” and “LOW” when logical
“0”.
Approx. 5µs pulse.  "LOW" indicates that
data has been received and that the printer
i s   r e a d y   t o   a c c e p t   o t h e r   d a t a .
A "HIGH" signal indicates that the printer
cannot receive data. The signal becomes
“HIGH” in the following cases:
1. During data entry
2. During printing operation
3. In OFF-LINE state
4. During printer error status.
A “HIGH” signal indicates that the printer
is out of paper.
- 8 7 -