Epson 7000 Benutzerhandbuch

Seite von 231
EPSON Stylus Pro 7000
Revision B
Disassembly & Assembly
Disassembly Flow
148
4.2.3.16  Removing the Pump Assembly 
1.
Remove the Maintenance Assembly as described in “Removing the 
Maintenance Assembly” on page 143.
2.
Remove the Cap Assembly as described in “Removing the Cap 
Assembly” on page 147.
3.
Remove the two (CUPS M3x6) screws securing the pump reduction gear 
bracket and remove the pump reduction gear bracket and pump gear.
NOTE: When mounting the pump reduction gear, make sure the 
reduction gear mesh with the corresponding gear.
4.
Remove the one (CUPS M3x6) screw securing the Pump Assembly and 
remove the Pump Assembly.
Figure 4-73.  Removing the Pump Assembly
4.2.3.17  Removing the Cleaner Head
1.
Remove the Maintenance Assembly as described in “Removing the 
Maintenance Assembly” on page 143.
2.
Remove the Cap Assembly as described in “Removing the Cap 
Assembly” on page 147.
3.
Using tweezers, release the joint for the concave part of the Cleaner Head 
and the convex part of the Cleaner Head support part in the Pump Assy. 
Then remove the Cleaner Head by pulling it upward.
NOTE: Set the Cleaner Head in the correct direction, and do not touch 
the Cleaner Head with your bare hands.
Figure 4-74.  Removing the Cleaner Head
Pump 
Reduction Gear 
Bracket
Pump
Screw 
(M3x6)
Pump Gear
Screws 
(M3x6)
Cleaner Head 
(Front part is 
rubber)
Tweezers
Pump 
Assembly