Electrical
Mechanical
Paper 
The allowable paper dimensions are shown below: 
Notes:
❏ Poor quality paper may reduce print quality and cause paper jams 
and other problems. If you encounter problems, switch to a 
higher grade of paper.
❏ Do not use curled, folded, or deckle-edge paper.
❏ Depending on the media, best feed and print quality are 
guaranteed on EPSON paper with thicknesses of 3.15 to 4.33 mil 
(0.08 to 0.11 mm), 64 to 90 gsm. 
❏ For best results, use paper under the following conditions:
Temperature:
59 to 77 °F (15 to 25 °C)
Humidity:
40 to 60% RH
Environmental
Safety Approvals
Ink Cartridges
Specification
120V Model
220
240V Model
Input voltage range
90 to 132V
198 to 264V
Rated frequency range
50 to 60 Hz
Input frequency range
49 to 61 Hz
Rated current
1.4 A
0.7 A
Power consumption
Approx. 131 W (ISO 10561 Letter Pattern)
30 W or less in sleep mode
Dimensions
Width: 73.4 inches (1865 mm)
Depth: 28.0 inches (710 mm)
Height: 48.2 inches (1225 mm)
Weight
284 lb (129 kg) with stand
Roll paper
Cut sheets
Size
8.3 to 44 in. wide 
(210 to 1118 mm)
8.5 × 11 in. up to 44 in. 
wide
Maximum 
external roll 
diameter
2 in. core: 4 in. (103 mm)
3 in. core: 6 in. (150 mm)
Thickness
3.15 to 19.7 mil (0.8 to 
0.5 mm)
3.15 to 59 mil (0.8 to 
1.5 mm)
Temperature
Operation: 50 to 95 °F (10 to 35 °C)
Storage:
4 to 104 °F (
20 to 40 °C)
1 month at 104 °F (40 °C) 
Transit
4 to 140 °F (
20 to 60 °C),
stored in shipping container 
120 hours at 140 °F (60 °C)
Humidity
(without 
condensation)
Operation:  20 to 80% RH
Storage: 
20 to 85% RH 
Transit
5 to 85% RH (stored in
shipping container)
Safety standards UL 1950, CSA C22.2 No. 950 FDA
EMC
FCC part 15 subpart B, class A,
CSA C108.8 class A
Cartridge life:
Photographic Dye ink
2 years from production date 
UltraChrome and Archival ink
2 years from production date if unopened; 
within 6 months after opening package, at 
77 °F (25 °C)
Temperature:
Storage (uninstalled):
22 to 104 °F (
30 to 40 °C); 1 month at 104 
°F (40 °C)
Storage (installed):
4 to 104 °F (
20 to 40 °C); 1 month at 104 
°F (40 °C) 
Transit
:
22 to 140 °F (
30 to 60 °C); 1 month at 104 
°F (40 °C), 120 hours at 140 °F (60 °C)
Freezing:
14 °F (
10 °C); ink thaws and is usable after 
at least 3 hours at 77 °F (25 °C)
Capacity
500 ml