Printronix LQH-HWTM Benutzerhandbuch

Seite von 302
 164
Chapter
3
Bar Codes
PostBar and Royal Mail Command Format
BARCODE
POSTBAR or ROYALBAR; [KIX;][
MAG;][BFn;L;][DARK;] SR; SC
[
(D)data field(D)]
STOP
BARCODE
The Bar Code command; enter BARCODE.
POSTBAR or ROYALBAR
Designates bar code type PostBar or Royal Mail; 
enter POSTBAR or ROYALBAR.
KIX
Optional parameter to specify the KIX format for 
Royal Mail bar codes only; enter KIX.
MAG
Optional parameter to magnify (horizontally 
expand) the bar code symbol. The magnification 
default value is X1. As required for scanning, enter 
a magnification value from Table 8 to increase the 
magnification. Increasing the magnification adjusts 
printed character density. X1A uses shorter bars to 
reach the minimum height specification that allows 
it to fit on a 6 LPI line.
BF
n;L
Optional parameters for assigning a dynamic bar 
code data field location on a form and for 
designating the length of the data field. With these 
parameters, the actual data for the bar code data 
field is provided dynamically during the Execute 
Form mode; the data is not specified during the 
Create Form mode. To use this field, perform the 
following steps:
a.
Enter BF.
b.
Replace 
n with a number ranging from 1 
through 512 to identify the bar code field. The 
SR and SC parameters specify the exact 
location of the bar code field identified by 
n.
c.
Replace 
L with a number equaling the total 
number of characters in the field. The data 
field must be numeric and contain exactly 5, 9 
or 11 digits.
d.
The information for the data field is entered 
dynamically during the Execute Form mode. 
(Refer to “Execute Form: Dynamic Bar Code 
Data” on page 63.) Do not use the 
data field 
parameter to enter data when the BF
n;L 
parameters are used. However, refer to the 
data field description for available characters. 
DARK
Optional parameter to produce darker looking bar 
codes. Enter DARK. Refer to “Dark Printing” on 
page 28 for more information.