Command Codes
STOP
Stop indicates the end of the CORNER command; 
enter STOP, and the IGP will wait for a new 
command. If not entered, the IGP will wait for 
another set of Corner command parameters. 
Example
The following program specifies a corner set as shown in Figure 
6. To illustrate positioning, the starting row and column are 
indicated on the example but do not necessarily reflect actual 
location on the page. (Note the position of the ending row and 
ending column; they do not include the line thickness.)
CORNER
5;27;27;42;55;4;6
(Each corner in the set is 5
STOP
dot rows thick, 4 character
rows high, 6 character columns
wide)
Figure 6. Corner Example
COLUMN 27
ROW 27
COLUMN 55
ROW 42
HORIZONTAL LENGTH
6 COLUMNS
VERTICAL
LENGTH
4 ROWS