Printronix T5000R Benutzerhandbuch

Seite von 102
Error Messages
93
The printed labels look clean, but 
the validator is still reporting an 
error message.
The validator glass may be dirty, distorting the 
report results. Power down the printer and clean 
the glass using a household glass cleaner and a 
dry, lint-free cloth.
The printed bar codes are 
causing error conditions.
There are a number of factors which could be 
causing validation errors:
The scanning beam is not properly aligned 
with the two notches on the tear bar of the 
printer. See “Adjust The Scanning Beam” on 
page 27.
Make sure the entire bar code passes 
completely under the scanning beam.
The validator and printer are not properly 
communicating. Test the validator operation 
without using a host. See “Bar Code 
Validation Demo Page” on page 36.
Bar code width. The validator can recognize 
x-dimensions as narrow as 6.6 mil for 
300 dpi printers, and 10 mil for 203 dpi 
printers. The validator cannot recognize
x-dimensions smaller than 6.6 mil or larger 
than 40 mil.
Bar code size. A minimum height of 1/8 inch 
is required for validation. If problems persist, 
increase the bar code height.
Bar code type. The validator only 
recognizes the following linear, picket fence 
bar codes: Codabar, Code 39, Code 93, 
Code 128, Interleaved 2 of 5, and
UPC/EAN. Stacked, 2D, and vertical 
(ladder) bar codes are not supported.
Table 7. Troubleshooting the Validator
Symptom
Solution