Monitoring and Configuring the Printer
248
6
wiconfig
Use the “wiconfig” command to make settings for IEEE 802.11b.
❖ View settings
msh> wiconfig
❖ View IEEE 802.11b settings
msh> wiconfig cardinfo
• If IEEE 802.11b is not working correctly, its information is not displayed.
❖ Configuration
msh> wiconfig “parameter”
Parameter
Value configured
mode {ap|adhoc|802.11adhoc}
You can set the infrastructure mode (ap) , the 
802.11 ad hoc mode (802.11adhoc), or the ad hoc 
mode (adhoc).
The default is ad hoc mode.
ssid “ID value
You can make settings for the SSID in the infra-
structure mode.
Usable characters are ASCII 0x20-0x7e (32 bytes).
An SSID value is set automatically to the nearest 
access point if no setting is made.
If no setting is made for the ad hoc mode, the same 
value as for the infrastructure mode or an ASSID 
value is automatically set. The default is blank.
channel frequency “channel no.
You can enable or disable the WEP function. To en-
able the WEP function, specify [on]; to disable it, 
specify [off].
To start the WEP function, enter the correct WEP 
key. The default is “11”.
key “key value” val {1|2|3|4}
You can specify the WEP key when entering in 
hexadecimal.
With a 64-bit WEP, you can use 10 digit hexadeci-
mals. With a 128-bit WEP, you can use 26 digit 
hexadecimals.
Up to four WEP keys can be registered. Specify the 
number to be registered with “val”.
When a WEP is specified by key, the WEP speci-
fied by key phrase is overwritten.
To use this function, set the same key number and 
WEP key for all ports that transmit data to each 
other. Put “0x”on the front of WEP key.
You can omit the numbers with “val”. The key 
number is set to 1 when making these omissions. 
The default is blank.