Savin 9922DP Benutzerhandbuch

Seite von 163
Replacing Photo Conductor Unit (PCU)
95
3
E
Raise the green handle and slide the photo conductor unit out towards you.
Important
❒ Do not tilt or drop the removed photo conductor unit. Moving the unit
abruptly can scatter the toner.
❒ While the photo conductor unit is removed, do not change the toner.
F
Take the new photo conductor unit from the box and remove the plastic
bag, holding the handle.
Important
❒ Do not drop or damage the removed photo conductor unit.
❒ Do not touch the side of the photo conductor unit.
G
Put the photo conductor unit removed in step 
E into the plastic bag emptied
in step 
F, keeping the unit at the same angle as when it was installed. Then,
zip the plastic bag.
Note
❒ Do not tilt the used PCU after Removing it from the machine. If you do,
toner might fall.
H
Remove the two red sheets from the photo conductor unit in the order
shown in the illustration.