HP (Hewlett-Packard) 70 Benutzerhandbuch

Seite von 140
Define State Trigger Term "e" and Range1
The trigger term "e" stores one value.  The Range1 term, however, can store a
range of values.  Storing a range of values is useful when you are looking to
store the data of a subroutine or procedure.
1
Turn the knob clockwise to display the 
e
 term in the bottom left
corner of the display.  Under SCOUNT, highlight the field to the right
of 
e
.  Enter 059 using the keypad.  Press the 
Done
 key.
2
Turn the knob until the Range1 term is displayed.  Highlight the field
to the right of 
upper
 and enter 058 using the keypad.  Press the 
Done
key.
3
Highlight the field to the right of 
lower
 and enter 050 using the
keypad.  Press the 
Done
 key.
Defining State Trigger Terms "e" and Range1
Result
The trigger term "e" is assigned the decimal value 059, and Range1 is
assigned decimal values 050 through 058.
Advanced State Triggering
Define State Trigger Term "e" and Range1
6-6