Hardware
Installing the LCS60
comment
A description of the entry.
hardware type
The fiber interface hardware for the LCS60 always con-
nects to the CPM-HS.
connect-time
Specifies if billing information is to be logged.
number of channels
Enter 512.
connect time billing
This is not used for the LCS60.
Single or multiple
Enter single.
group
Enter the group from the previous operation.
Endpoint
This is not used for the LCS60.
restore
The CPM-HS module must be restored to service before
it can be used.
Power and Grounding
Connect the AC power cord provided to a three-wire grounded 110 VAC recep-
tacle and the LCS60 rear panel power receptacle as shown in Figure 2-7.
Connect DC power as shown in Figure 2-7.
Power-Up Procedures
Follow the steps below for LCS60 power up only after reading this section.
1 .  Connect the LCS60 to the power source.  For the AC power unit, the outlet
should be on a dedicated circuit for the LCS60.
2 .  Power up the system console. (Refer to the section Connecting the System
Console.)  If the system console is connected to the LCS60 by means of a
data switch network, enter the appropriate console name (entered in
Screens 2-1 or 2-2) in response to the
DESTINATION
prompt.
3 .  Power up the LCS60 by turning the on/off switch to on.
Issue 3 