Mitsubishi Electronics QD75MH2 Benutzerhandbuch

Seite von 838
 
 
 
8 - 5 
MELSEC-Q
 
8   OPR CONTROL 
 
8.2 Machine OPR 
8.2.1 Outline of the machine OPR operation 
 
Important 
 
Use the OPR retry function when the OP position is not always in the same 
direction from the workpiece operation area (when the OP is not set near the upper 
or lower limit of the machine). 
 The machine OPR may not complete unless the OPR retry function is used. 
 
 
 Machine OPR operation 
 
In a machine OPR, OP is established. 
None of the address information stored in the QD75MH, PLC CPU, or servo is used at 
this time. The position mechanically established after the machine OPR is regarded as 
the "OP" to be the starting point for positioning control.  
The method for establishing an "OP" by a machine OPR differs according to the method 
set in "
Pr.43
 OPR method".  
The following shows the operation when starting a machine OPR.  
 
1) 
The "machine OPR" is started. 
2) 
The operation starts according to the speed and direction set in the OPR parameters 
(
Pr.43
to
Pr.57
). 
3) 
The "OP" is established by the method set in "
Pr.43
 OPR method", and the 
machine stops. (Refer to sections 8.2.2 to 8.2.8) 
4) 
If "a" is set as "
Pr.45
 OP address", "a" will be stored as the current position in the 
"
Md.20
 Current feed value" and "
Md.21
 Machine feed value" which are 
monitoring the position. 
5) 
The machine OPR is completed. 
 
 The "
Pr.45
 OP address" is a fixed value set by the user. 
 
M
OP
Near-point dog
Machine OPR
 
Fig. 8.2 Example of a machine OPR