 Positioning data setting example 
 
[Reference axis and interpolation axis are designated as axis 1 and axis 2, 
respectively.] 
The following table shows setting examples when "2-axis circular interpolation 
control with sub point designation (ABS circular sub)" is set in positioning data No. 
1 of axis 1. (The required values are also set in positioning data No. 1 of axis 2.) 
 
Axis 
 
Setting item 
Axis 1 
(reference 
axis) setting 
example 
Axis 2 
(interpolation 
axis) setting 
example 
Setting details 
 Da.1  Operation pattern 
Positioning 
complete 
– 
Set "Positioning complete" assuming the next positioning 
data will not be executed. 
 Da.2  Control system 
ABS circular 
sub 
– 
Set absolute system, 2-axis circular interpolation control 
with sub point designation. 
 Da.3  
Acceleration time 
No. 
1 – 
Designate the value set in "
Pr.25
 Acceleration time 1" as 
the acceleration time at start. 
 Da.4  
Deceleration time 
No. 
0 – 
Designate the value set in "
Pr.10
 Deceleration time 0" as 
the deceleration time at deceleration. 
 Da.5  
Axis to be 
interpolated 
2 – 
Set the axis to be interpolated (partner axis). 
If the self-axis is set, an error will occur. 
 Da.6  
Positioning address/ 
movement amount 
8000.0 µm  6000.0 
µm 
Set the positioning address. (Assuming "mm" is set in 
"
Pr.1
 Unit setting".) 
 Da.7  Arc address 
4000.0 µm  3000.0 
µm  Set the sub point address. (Assuming that the "
Pr.1
 Unit 
setting" is set to "mm".) 
 Da.8  Command speed 
6000.00 
mm/min 
– 
Set the speed when moving to the end point address. 
(Designate the composite speed in "
Pr.20
 Interpolation 
speed designation method".) 
 Da.9  Dwell time 
500ms 
– 
Set the time the machine dwells after the positioning stop 
(pulse output stop) to the output of the positioning complete 
signal. 
Ax
is 1   Positioning data N
o. 1 
 Da.10 
M code 
10 
– 
Set this when other sub operation commands are issued in 
combination with the No. 1 positioning data. 
 
     Refer to Section 5.3 "List of positioning data" for information on the setting details.  
 
POINT 
 
Set a value in "
Da.8
 Command speed" so that the speed of each axis does not 
exceed the "
Pr.8
 Speed limit value". (The speed limit does not function for the 
speed calculated by the QD75MH during interpolation control.)