IBM TI5 Benutzerhandbuch
Set Sheet Eject Length
RS-232 Syntax:
ESC C n or X'1B43;n'
where:
n
Specifies the number of line feed steps using minimum units moved
when a FF is sent in the receipt station.
when a FF is sent in the receipt station.
In the document station, an eject will feed until the document has
exited the lower document sensors - this length is not used.
exited the lower document sensors - this length is not used.
Default:
n = X'A0' (160 decimal)
Maximum:
255 steps (X'FF')
This value is stored in the EEPROM in the printer so that it is not lost when the
printer is reset.
printer is reset.
Set Horizontal Tab Positions
RS-232 Syntax:
ESC D [n1 n2] NUL NUL or X'1B44[n1n2]0000'
where:
n1
The high-order-byte dot offset for the horizontal tab.
n2
The low-order-byte dot offset for the horizontal tab.
Default:
There is a tab every 100 dots.
Remarks:
This command should be sent after “Set Print Station Parameters” on
page 130.
page 130.
Up to 5 tab positions can be stored. All 5 n1 n2 value pairs can be included
in one command. Values must be entered in hex.
in one command. Values must be entered in hex.
A tab is calculated from the left margin position.
Tab values must be in ascending order.
Example: To set 3 tab positions - at the 100, 150 and 300 dot positions:
v X'1B4400640096012C0000'
v X'1B4400640096012C0000'
Set Left Margin Position
RS-232 Syntax:
ESC $ n1 n2 or X'1B24;n1;n2'
where:
n1
The high-order byte of the dot offset from the beginning of the print
line.
line.
n2
The low-order byte of the dot offset from the beginning of the print
line.
line.
updated March 18, 2002
Appendix C. RS-232 Programming Information
133