Zebra Technologies Z6000 Benutzerhandbuch

Seite von 98
Communication Interfaces
Data cables must be fully shielded and fitted with metal or metalized
connector shells to prevent radiation and reception of electrical noise.
To minimize electrical noise pickup in the cable:
n
Keep data cables as short as possible.
n
Do not bundle the data cables tightly with power cords.
n
Do not tie the data cables to power line conduits.
Serial Data Communications
Table 11 illustrates the pin connections on the DB-25 connector at the
rear of the printer.
Series™ User’s Guide
71
Appendix B
PIN NO.
DESCRIPTION
1
Chassis Ground
2
TXD (Transmit Data) output from the printer
3
RXD (Receive Data) input to the printer
4
RTS (Request To Send) output from the printer
5
Not Used
6
DSR (Data Set Ready) input to the printer
7
RS-232 Signal Ground
8
Not Used
9
+5V @ 1A source
10
Not Used
11
RS-485 Signal Ground
12
Not Used
13
RS-485 Input B (-)
14
RS-485 Output B (-)
15
Not Used
16
RS-485 Input A (+)
17-18
Not Used
19
RS-485 Output A (+)
20
DTR (Data Terminal Ready) output from the printer
21-25
Not Used
Table 11. Rear Panel Serial Data Port Pinout