Zebra Technologies R110Xi Benutzerhandbuch

Seite von 184
64
R110Xi/R170Xi User Guide
23063L-003 Rev. 1 12/6/04
Front Panel Controls
Front Panel LCD
RFID TAG DATA
Read and Display RFID Tag Data
When this option is selected, the reader attempts to read a tag over the reader, even 
if the printhead is open. If no tag data can be read, the text 
NO DATA
 appears on 
the bottom line of the display.
If a tag is present, the data for that tag appears on the bottom line of the display in 
hexadecimal format. If there is more data than can fit on the bottom line (such as for 
96-bit tags), the bottom line will cycle from the first 8 bytes (most significant) to the 
next 4 bytes (least significant) approximately every 2 seconds. Whatever 
hexadecimal data that can fit on two screens is displayed and cycled through.
For example, if the tag contains the data 
0x112233445566778899001122
when this option is selected, the bottom line of the display shows: 
1122334455667788
 for 2 seconds followed by 
99001122
 for 2 seconds. The 
printer cycles through these indefinitely.
The printer rereads the tag every cycle, so if the tag changes, data is displayed for 
the current tag over the antenna.
Table 9 • RFID LCD Displays (Continued)
Parameter