Z4Mplus and Z6Mplus User Guide
Routine Care and Adjustments
Cleaning Procedures
Cleaning Procedures
Specific cleaning procedures are provided on the following pages. Below is a 
recommended cleaning schedule.
Area
Method
Interval
Printhead
Solvent*
Direct Thermal Mode:  After 
every roll of media (or 500 feet of 
fanfold media).
Thermal Transfer Mode:  After 
every roll of ribbon or three rolls of 
media.
These intervals are intended as 
guidelines only. You may have to 
clean more often, depending upon 
your application and media.
Platen roller
Solvent*
Media sensors
Air blow
Ribbon sensor
Air blow
Media path
Solvent*
Ribbon path
Solvent*
Pinch roller. (Optional peel-
off option required. Refer to 
.)
Solvent*
Cutter 
Module
If cutting 
continuous, 
pressure-sensitive 
media
Solvent*
After every roll of media (or more 
often, depending upon your 
application and media).
If cutting tag stock 
or label liner 
material
Solvent* 
and air 
blow
After every two or three rolls of 
media.
Tear-off/peel-off bar
Solvent*
Once a month.
Take label sensor
Air blow
Once every six months.
* Zebra recommends using the Preventive Maintenance Kit, Part Number 47362 or a solution of 90% Isopropyl and 10% 
deionized water)