Zebra Technologies 105S Benutzerhandbuch

Seite von 110
46
Zebra S-Series User’s Guide
,QWHUIDFHV
The method of interfacing the Zebra S-Series Printer to a data source 
depends on the communication options installed in the printer.  Depending 
on how the printer was ordered, the interface is either an RS-232 serial 
data port or a parallel port.
'DWD6SHFLILFDWLRQV
When communicating via the serial data port (RS-232), the baud rate, 
number of data bits, and the parity are user-selectable (see Table 1 on 
page 40 f
or acceptable setting combinations).  Parity only applies to data 
transmitted by the printer, since it ignores the parity of received data.  The 
S-Series Printer is fixed at 1 stop bit, so make sure that your host is also set 
at 1 stop bit.
When communicating via the parallel port, the previously mentioned 
parameters are not considered.
566HULDO'DWD3RUW
The connections for the standard interface are made through the DB-25S 
connector on the rear panel.  For all RS-232 input and output signals, the 
S-Series Printer follows both the Electronics Industries Association’s 
(EIA) RS-232 and the Consultative Committee for International Telegraph 
and Telephone (CCITT) V.24 standard signal level specifications.  
563LQRXWV
Table 3
Pin No.
Description
1
Frame Ground for Cable Shield
2
TXD (Transmit Data) output from the printer
3
RXD (Receive Data) input to the printer
4
RTS (Request to Send) output from the printer
6
DSR (Data Set Ready) input to the printer
7
Signal Ground
20
DTR (Data Terminal Ready) output from the printer
Note:  Pins 5, 8, 10-19, and 21-25 are unused and unterminated.