Operations
Calibrate the Printer
60
79695L-002 Rev. A
Z Series
®
/RZ™ Series User Guide
6/6/08
Calibrate the Printer
The printer can be set to calibrate automatically, or you can calibrate it manually.
Auto Calibration
When the control panel setting for 
MEDIA POWER UP
 or 
HEAD CLOSE
 is set to 
CALIBRATION
, the printer automatically calibrates on power up or when the printhead is 
closed. During auto calibration, the printer determines the label length and sensor settings. The 
results of the auto calibration are stored in the printer’s memory and are retained even if printer 
power is removed. These parameters remain in effect until the next calibration is performed.
Manual Calibration
Perform a media and ribbon sensor calibration to reset the sensitivity of the sensors so the 
media and ribbon are detected more accurately. If you change the type of ribbon or media, 
your printer may operate better if you perform this calibration.
.
Note • 
If the control panel settings for 
MEDIA POWER UP
 or 
HEAD CLOSE
 are set to 
LENGTH, NO MOTION, or FEED, the printer starts printing without auto calibrating. See