Zebra Technologies EPL2 Benutzerhandbuch

Seite von 138
<Esc>
p
Command - Generate Pulse CDK
Description Generate a drawer kicker pulse.
Syntax
<Esc>pp
1
p
2
p
3
Parameters
p
1
= Select Drawer
Drawer 1 (SDRV1) = 31 hex.
Drawer 2 (SDRV2) = 32 hex.
p
2
= Pulse “on” time in multiples of two milli-
seconds (2 msec).
Range = 00 - FF hex.
p
3
= Pulse “on” time in multiples of two milli-
seconds (2 msec). The value of
p
3
must
be greater than or equal to the value of
p
2
.
ASCII Hex Value 1B 70
p
1
p
2
p
3
(
p
1
represent value range 31 to 32 hex;
p
2
represent value range 00 to FF hex;
p
3
represent value range 00 to FF hex)
Example
←p2Bd↵
: ←p = <Esc>p , the command
: 2 = p1 parameter value of 32 hex.
: B = p2 parameter value of 42 hex. for
:
132 msec pulse  (66 x 2msec)
: d = p3 parameter value od 64 hex. for
:
200 msec. pulse  (100 x 2msec)
980352-001 Rev.A
B-3