Siemens PANEL PC 877 Benutzerhandbuch

Seite von 288
 
Detailed descriptions 
 
17.1 Motherboard 
SIMATIC Panel PC 877 
Operating instructions, Release 07/2006, A5E00877780-01 
17-13
 
17.1.5 
Front interfaces 
Overview 
 
Interface 
Position 
Connector 
Description 
Display (LVDS) 
Internal 
X300 
Connection of LCD displays with 
LVDS interface (channel 1) 
Display (LVDS) 
Internal 
X310 
Connection of LCD displays with 
LVDS interface (channel 2) 
I/O front 
Internal 
X44 
Interface for I/O front 
COM2 
Internal 
X33 
Internal COM2 interface 
USB  
Internal 
X2033 
Internal USB 2.0 interface (USB 
channel 5) 
Display interfaces 
TFT displays with an LVDS interface can be connected to this interface. You may connect 
18-bit displays with a resolution up to 1024x768 pixels on X300 only (single-channel LVDS), 
and of 1280 x 1024 pixels on X300 and X301 (dual-channel LVDS). X301 is also connected 
to a +12VF at max. 4.2. A power supply for backlight inverters for 17" / dual-channel LVDS 
displays. The permitted display clock rate is 20MHz to 66MHz. The display is selected 
automatically according to the coding of the display select inputs. 
The display power supply voltages (3.3V and 5V) are switched via the graphic controller, 
independent of the requirements of the connected display units. The maximum cable length 
is 50 cm at a transmission rate of 455 MHz. Make allowances for the special channel 
features of differential line pairs with LVDS specifications.